Description
The LT4000 series battery pack test system is a fully automatic programmable battery pack comprehensive test system developed by Wright Company according to the characteristics of the battery pack. It can simulate various actual operating conditions such as electric vehicles, energy storage power stations, and communication power supplies.
The LT4000 series battery pack test system is a fully automatic programmable battery pack comprehensive test system developed by Wright Company according to the characteristics of the battery pack. It can simulate various actual operating conditions such as electric vehicles, energy storage power stations, and communication power supplies. The device is built with advanced IGBT energy feedback module, combined with DSP digital processing technology and high-precision sampling control technology, which can charge, discharge and test battery pack capacity in a specific mode for new energy battery modules or battery packs. It can also test various electrical properties of battery packs of different specifications according to international and domestic testing standards. Through the test data, the group quality of power batteries can be comprehensively and comprehensively evaluated and factory consistency inspection and screening.
The Wright battery pack test system has the characteristics of accurate current and voltage detection, complete data acquisition and processing functions, high efficiency and energy saving and no pollution to the power grid, which provides a safe and reliable guarantee for the research and production of new energy electric vehicle battery packs.
technical parameter
equipmentname | Battery Pack Test System | |||
equipmentmodel | LTM4000 | |||
Device channel | 2CH, 4CH | |||
equipmentSpecification | 120V300A2CH | 500V300A4CH | 750V500A2CH | 1000V800A2CH |
Electricityflowscope | -300Aadd 300A | -300Aadd 300A | -500Aadd 500A | -800Aadd 800A |
ElectricityStreaming Accuracy | ±0.05Percent FS,±0.02 Percent FSoptional | |||
Current range | Single range and dual range optional | |||
ElectricityPressure range | 0V 120V,0V50V,0V750V,0V1500Voptional | |||
Voltageprecision | ±0.05Percent FS,±0.02 Percent FSoptional | |||
numberdata collection | standard10mS | |||
controlmodel | constantflowmodel,constant pressuremode, constant current and constant voltage mode,Constant powerRate,constant resistance, pulse, working condition test, etc. | |||
optionalAccessories | Auxiliarytemperatureaisle, auxiliary voltageaisle, auxiliary pressure channel,CANcommunicationFeatures,BMScommunication,Thermistor input, digitalInput and output powercan, third-party equipment joint controlWait | |||
equipmentsize | 2125px(W) X 2125px(D) X 4750px(H) 3000px(W) X 2125px(D) X 4750px(H) | |||
Application scenarios | 1.New energy battery test 2.Electric Vehicle Battery Test 3.New energy vehicle battery test 4.Electric boat mooring battery test 5.Energy storage battery test 6.Rail transit battery test 7.Product development and application 8.laboratory application 9.Experiment Application in Colleges and Universities 10.Academic research in research institutes |